Filter

High pressure filter
High pressure


















Medium pressure filter series HMM

Medium pressure series HMM for building in the pipeline to 170 l/min and max. 220 bar

Constructional sizes :
HMM 281 – 282 – 283 – 421 - 422
Qmax = 170 l/min in pressure line near Pmax = 220 bar

Accessories : optical or electric pollution index
Filter type : CHP

Kinds of filters :
paper, inorganic fiber, metal fabric

Exactitude of filtering: 3,6,10,25 microns
   


  Return flow filter series OMTP

Return flow filter for building in tank to 500 l /min with combined purger and bayonet (optional)
Constructional sizes: OMTP 20 - 100
Qmax = 175 l/min

Accessories: optical or electric pollution index
Filter type: OMTPR

Kinds of filters: paper, inorganic fiber, metal fabric
Exactitude of filtering: 3,6,10,25,60,90 or 125 microns

SPIN-ON filter series OMTI

The filter of return flow for building in tank to 500 l / min

Constructional sizes: OMTI 05 – 06 – 10 -15 – 20 -25 – 31- 36
( old OMTF 40 – 65 – 85 - 100 – 150 – 200 – 280 – 300 - 350 )
Qmax = 500 l/min in backward flow

Accessories: optical or electric pollution index

Filter type : CS

Kinds of filters : paper, inorganic fiber, metal fabric
Exactitude of filtering: 3,6,10,25,60,90 or 125 microns

Also filter with head for direct buildings in tank - type FTT (picture on the left side)

Suction filter / return flow filter series AFI

As suction filter or return flow filter for building in tank to 1200 l / min in return flow or in suction movement 550 l / min.

Constructional sizes: AFI 025 – 040 – 100 – 250 – 630- 850
(old AFR 30 – 60 – 100 –180)
Qmax = 1200 l /min in backward flow
550 l /min im suction movement

Accessories: optical or electric pollution index
Filter type: CFI

Kinds of filters: paper, inorganic fiber, metal fabric
Exactitude of filtering: 3,6,10,25,60,90 or 125 microns

To chose with or without bypass.

Suction filter series AFR

Suction filter for building in pipelines or tanks to 200 l /min.

Constructional sizes: AFR 091 – 111 – 112 - 171
(old AFR 30 – 60 – 100 –180)
Qmax = 200 l/min

Accessories: optical or electric pollution index
Filter type: CR (old CA)

Kinds of filters: paper, inorganic fiber, metal fabric
Exactitude of filtering: 3,6,10,25,60,90,125 or 250 microns

To chose with or without bypass.

  Return flow filter series OMTF

Return flow filter for building in tank to 500 l/min

Constructional sizes: OMTF 09 – 17 – 11 – 22
(old OMTF 40 – 65 – 85 - 100 – 150 – 200 – 280 – 300 - 350)
Qmax = 500 l /min in backward flow

Accessories: optical or electric pollution index

Filter type: CR

Kinds of filters: paper, inorganic fiber, metal fabric

Exactitude of filtering: 3,6,10,25,60,90 or 125 microns